We are supported by some of the most qualified and technically sound professionals, who are well aware about different techniques required to manufacture products. Our team members hold vast industry experience, which help them in sourcing quality raw material from reputed vendors. They are well versed with the quality testing process of these precision engineered components.
Engineers
Quality controllers
R & D experts
Skilled workers
Warehouse professional
Specification | Allowable Outside Diameter Variation in mm | Allowable Wall Thickness Variation | Exact Length Tolerance in mm | Testing | ||||
Nominal Diameter | Over | Under | %Over | %Under | Over | Under | ||
ASTM-A213 Seamless Boiler Superheater and Heat Exchanger Tubes | Under 25.4 | .1016 | .1016 | +20 | -0 | 3.175 | 0 | Flattening Test |
25.4-38.1 incl | .1524 | .1524 | +22 | -0 | 3.175 | 0 | Tension Test | |
38.1-50.8 excl | .2032 | .2032 | +22 | -0 | 3.176 | 0 | Flare Test | |
50.8-63.5 excl | .254 | .254 | +2 | -0 | 4.46 | 0 | Hardness Test | |
63.5-76.2 excl | .3048 | .3048 | +22 | -0 | 4.76 | 0 | 100% Hydrostatic test | |
76.2-101.6 incl | .381 | .381 | +22 | -0 | 4.76 | 0 | Refer to ASTM A-450 | |
ASTM-A249 Welded Boiler Superheater, Heat Exchanger And Condenser Tubes | Under 25.4 | .1016 | .1016 | +10 | -10 | 3.175 | 0 | Tension Test |
25.4-38.1 incl | .1524 | .1524 | +10 | -10 | 3.175 | 0 | Flattening Test | |
38.1-50.8 Excl | .2032 | .2032 | +10 | -10 | 3.175 | 0 | Flange Test | |
50.0-63.5 excl | .254 | .254 | +10 | -10 | 4.762 | 0 | Reverse Bend Test | |
63.5-76.2 excl | .3848 | .3848 | +10 | -10 | 4.762 | 0 | Hardness Test | |
76.2-101.6 incl | .381 | .381 | +10 | -10 | 4.762 | 0 | 100% Hydrostastic Test Refer to ASTM A-450 | |
Minimum Wall tubes +18% 0 available On request | ||||||||
ASTM-A269 Seamless & Welded Tubing for General Service | Untp12.7 | .13 | .13 | +15 | -15 | 3.2 | 0 | Flare Test (Seamless Only) |
12.7-38.1 exc! | .13 | .13 | +10 | -10 | 3.2 | 0 | Flange Test (Welded Only) | |
38.1-88.9 excl | .25 | .25 | +10 | -10 | 4.8 | 0 | Hardness Test | |
88.9-139.7 excl | .38 | .38 | +10 | -10 | 4.8 | 0 | Reverse Flattening Test | |
139.7-203.2 excl | .76 | .76 | +10 | -10 | 4.8 | 0 | (Welded only) 100% Hydrostatic Test Refer to ASTM-A269 | |
ASTM-A270 Seamless & Welded Sanitary Tubing | 25.4 | .05 | .20 | +10.0 | -10.0 | 3.2 | 0 | Reverse flattening Test |
38.1 | .05 | .20 | +10.0 | -10.0 | 3.2 | 0 | 100% Hydrostastic Test | |
50.8 | .05 | .28 | +10.0 | -10.0 | 3.2 | 0 | External' polish on all tubes | |
60.5 | .05 | .28 | +10.0 | -10.0 | 3.2 | 0 | Refer to ASTM A-270 | |
76.2 | .08 | .30 | +10.0 | -10.0 | 3.2 | 0 | ||
101.6 | .08 | .38 | +10.0 | -10.0 | 3.2 | 0 | ||
ASTM-A312 Seemless & Welded pipe | 3.175-38.1 incl | .4 | .79 | Minimum Wall 12.5% under nominal wall Specified | 6.4 0 | 0 | Tension Test | |
38.1-1016 incl | .79 | .79 | 6.4 0 | 0 | Flattening Test | |||
101.6-203.2 imcl | 1.59 | .79 | 6.4 0 | 0 | 100% Hydrostatic Test | |||
(Normally Random Lengths ordered | Refer to ASTM A-530 | |||||||
ASTM A-358 Welded pipe | 219.08-750mm or 0.01 inch | +0.5% | -0.3 | 6.0 | Refer to ASTM A-530 |